In the ever-evolving landscape of mechanical engineering, Constant Rate of Extension (CRE) machines play a pivotal role in materials testing, research, and development. These machines are designed to apply a controlled, steady extension rate to specimens, allowing for precise analysis of material properties under varying conditions.
At the heart of CRE machines lies a crucial component that dictates their performance and accuracy: the servo motor. The servo motor serves as the powerhouse, driving controlled movements and ensuring the precision demanded by research and industrial applications. As we delve into the intricacies of servo motor-based CRE machines, it becomes evident that achieving optimal extension precision is not a mere luxury but a necessity.
Servo motors, designed for high-precision tasks, facilitate the controlled extension and retraction essential for accurate material testing. Their ability to translate electrical signals into precise mechanical movements makes them indispensable in applications demanding reliable and repeatable results.
The quest for precision in CRE machines is met with a unique set of challenges. Striking the right balance between precision, resolution, and displacement range is paramount. How can we ensure that the servo motor operates seamlessly under diverse conditions while delivering the accuracy required for intricate materials testing?
In this exploration, we will dissect the factors influencing extension precision in servo motor-driven CRE machines. From understanding resolution nuances to considering the impact of displacement range, we aim to unravel the complexities and offer insights into optimizing the performance of these machines. Join us on this journey as we navigate the intricate realm of extension precision and unveil the key considerations for achieving excellence in servo motor-based CRE applications.
The Metrics of Precision: Properties We Aim to Control
In the world of CRE machines, they stretch or compress materials at a steady speed. Throughout this process, they consistently measure and record the force applied to the material at various displacement points. Now, let’s look at the essential characteristics that shape their performance. These properties encapsulate the essence of precision in motion control and materials testing.
- Displacement Accuracy: The ability of the system to precisely position the specimen in accordance with the intended extension.
- Displacement Resolution: The smallest increment of movement that the system can detect and act upon
- Displacement Range (Max. value): The maximum distance over which the CRE machine can extend the specimen
- Speed Precision: The accuracy with which the machine can maintain a constant extension rate.
- Speed Range: The range of extension rates or speeds that the CRE machine can achieve.
- Speed Accuracy: The ability of the system to achieve and maintain the desired extension rate accurately.
Factors Influencing Precision
Let’s look at the factors that wield considerable influence over the key properties we’ve identified. While some factors are within our control, others present fixed parameters that shape the machine’s performance.
- Gear Ratio: Most of the Servo drives defines Electronic gear ratio which in principal is equivalent to mechanical gear ratio but can be changed easily
- PPR: Number of external pulse required to complete one full rotation of the servo motor
- Pitch: The distance between corresponding points on adjacent teeth in a gear or screw.
- Word Size: The number of bits used to represent a digital word in the control system e.g. PLC
Connecting the Dots
Now that we have seen the properties that we wish to control and the factors which might impact them, let’s try to understand how these are related.
When we use pulse mode control for servo motors, we’re making them move precisely by sending little signals (pulses) from a controller (like a PLC) to the servo drives, which then guides the motor. This controlled movement happens as the motor turns and causes something called a ball screw nut to shift horizontally. The trick is figuring out the exact connection between the number of pulses sent and how much the ball screw nut moves. This connection is uncovered through a step-by-step process called calibration. During calibration, we carefully move a part and keep track of both the pulses sent and the movement. This process helps us understand how to speak the language of servo motor control, giving us the ability to finely control constant rate of extension applications
In simple terms:
Current Displacement = Np * Pitch / PPR; where
Np = Number of external pulse sent for current displacement
Pitch = Pitch of the ball-screw
PPR = Number of external pulses required for 1 revolution of motor
Looks simple. Right! Well, not exactly. PPR is dependent on a number of factors like electronic gear ratio of the servo drive, mechanical gear ratio between servo motor and ball screw etc. Also, the ball screw pitch may not be precise and contain some error. Due to these reasons, we cannot rely on PPR and pitch to calculate the current displacement of screw nut. Instead, we use an indirect method, called displacement calibration, to accurately compute the current displacement.
Modified formula,
Current- Displacement = Np * Dc / Npc where;
Dc = Displacement used during calibration process
NPc = Number of external pulse sent during calibration
Does that mean the displacement calibration is not dependent on other influencing factors like gear ratio and pitch? Well, it is dependent on these factors. The devil lies in the details. Let’s dig a bit deeper.
Let’s try to understand how ‘Np * Dc / Npc’ will be computed. Assuming our controller (a PLC) which is sending these pulses to the servo drive uses 2 words (i.e. 32 bit resisters) to hold ‘Np’, ‘Dc’ and ‘NPc’ values:
The Max value of ‘Np * Dc’ can be 2,147,483,647 i.e. 2^31
That means, if the product of ‘Np’ and ‘Dc’ is greater than this value, it will lead to an Overflow. Let’s take an example: Say, if PPR is 10,000 and pitch is 5 mm. Just for the sake of understanding, let’s assume no gear is involved and all components are accurate,
1 revolution will displace the screw nut by 5mm.
Let’s say we carried out displacement calibration by moving the nut 500mm with displacement precision of 1 decimal point. If the current displacement is 800 mm then,
‘Np * Dc’ => (800/5) * 10,000 * 5,000 => 8,000,000,000 which is > the Max value.
Result will be an overflow!
With the current configuration, what will be the max displacement that we can achieve?
Max possible displacement = 2,147,483,647 * 5 / (5,000 * 10,000) = 214.74 mm
That’s pretty low, so how to increase this value? Well, we can do a couple of things:
1) Reduce the displacement during calibration
2) Reduce the PPR or,
Let’s try number #2 first. Let’s say we carried out displacement calibration by moving the nut 50mm with the precision of 1 decimal point. If, like the earlier case, the current displacement is 800 mm then,
‘Np * Dc’ => (800/5) * 10,000 * 500 => 800,000,000 which is < the Max value.
Result will NOT be an overflow!
With the current configuration, what will be the max displacement that we can achieve?
Max possible displacement = 2,147,483,647 * 5 / (500 * 10,000) = 2147.4 mm
But what’s the catch? Let’s see. In manual calibration which is done using a physical scale, there is always some observational error involved. For the sake of calculation, let’s assume that error was 0.25 mm. Let’s calculate again:
With 0.25 mm error, 50 mm was actually 50.25 mm
That means, Nc = (10,000 / 5) * 50.25 = 100,500 instead of 100,000
So, how much error will there be when the actual displacement is 800 mm?
Error at 800 mm => 3.98 mm
That means, lower the displacement used while calibration, higher may be the displacement error. So, ideally we should calibrate with much bigger value. But as we saw earlier the higher calibration-displacement values may lead to Overflow. Phew! What to do then. Let’s try to manipulate via #2 approach i.e. reduce the PPR instead of calibration-displacement.
We know that the PPR is dependent on gear ratio. Servo drives support electronic gear ratios which can be easily changed. Let’s reduce the PPR to 1000 by increasing the electronic gear ratio 10 times and look at the calculation again. Let’s say we carried out displacement calibration by moving the nut 500mm with the precision of 1 decimal point. If the current displacement is 800 mm then,
‘Np * Dc’ => (800/5) * 1000 * 5000 => 800,000,000 which is < the Max value.
Result will NOT be an overflow!
Max displacement = 2,147,483,647 * 5 / (5000 * 1000) = 2147.4 mm.
Error at 800 mm => 0.39 mm